ARES-G2 Rotational Rheometer

The ARES-G2 is a rotational rheometer for research and material development. Moreover, its separate motor and transducer remove motor inertia from the data. Bargal represents TA Instruments in Israel.

  • Separate motor and transducer (SMT)
  • Minimum transducer torque 0.05 µN·m (oscillation)
  • Integrated DMA mode
  • Active Temperature Control
תיאור

The ARES-G2 rheometer is a rotational rheometer from TA Instruments for research and material development. It separates the motor from the transducer. Also, this design eliminates inertial contributions to the measurement. In addition, labs use the ARES-G2 to relate chemistry to processing and end-use properties. In Israel, Bargal represents TA Instruments.

Who is the ARES-G2 rheometer for?

The ARES-G2 suits demanding research and material development. It is also valuable when you must link chemistry to processing and performance. Typical users include:

  • Polymer and materials scientists who study melts, thermosets and composites
  • R&D teams that also work with paints, inks, coatings and other complex fluids
  • Research groups that use advanced methods such as LAOS and OSP
  • Labs that also want rheology and solids testing (DMA) in one platform

Applications

  • Polymer melts and thermosets: curing, gelation and molecular weight
  • Paints, inks and coatings: flow curves, yield stress and thixotropy
  • Emulsions, suspensions and slurries: shear thinning and non-Newtonian flow
  • Materials from proteins to polymers, especially when chemistry must link to processing and end-use properties
  • Composites and solids: DMA in bending, as well as tension and compression

Key features

  • Separate motor and transducer (SMT), so it removes motor inertia from the measurement
  • Force and torque rebalance transducers, for normal-force and torque data
  • Active Temperature Control, so it measures both plate temperatures directly
  • Smart Swap environmental systems, standard on the instrument
  • Integrated DMA mode, plus LAOS, FT rheology and orthogonal superposition (OSP)
  • TRIOS software, so you can access raw data for deeper analysis

Technical specifications

Parameter ARES-G2
Minimum transducer torque, oscillation 0.05 µN·m
Minimum transducer torque, steady shear 0.1 µN·m
Maximum transducer torque 200 mN·m
Torque resolution 1 nN·m
Maximum motor torque 800 mN·m
Angular velocity range 1E-06 to 300 rad/s
Angular frequency range 1E-07 to 628 rad/s
Strain resolution 0.04 µrad
Normal force range 0.001 to 20 N
DMA axial frequency range 1E-05 to 16 Hz
Forced convection oven -150 to 600 °C
Advanced Peltier system -10 to 150 °C
Peltier plate -40 to 180 °C
Sealed bath -10 to 150 °C

 

You can also read the full details on the official TA Instruments ARES-G2 page.

Frequently asked questions

What does separate motor and transducer mean?

One part applies the deformation, and another part measures the stress. Because the transducer stays stationary, motor friction and inertia need no correction.

Can the ARES-G2 test solid samples?

Yes. Its integrated DMA mode tests solids in bending, tension and compression.

Does TA Instruments offer other ARES models?

Yes. TA Instruments also offers the ARES-G3 rheometer. See its dedicated page for details.

Interested in the ARES-G2? Send us an enquiry, and our team will respond quickly. We are also happy to discuss your samples and your application.

 

Also see the ARES-G3 rheometer.

For very low torque, see the Discovery HR 30 hybrid rheometer.

 

 

ראומטר ARES-G2 של TA Instruments, ראומטר סיבובי למחקר ולפיתוח חומרים עם מנוע ומתמר נפרדים ומצב DMA משולב – ברגל ציוד אנליטי, נציגת TA Instruments בישראל.

 

 

צרו קשר

היי! שמחים שהגעתם לאתר שלנו! באתר יש כרגע מאות מוצרים ואנחנו מוסיפים מוצרים כל הזמן. אם לא מצאתם את מה שחיפשתם או שאין לכם כוח לחפש (קורה לכולנו), כתבו לנו כאן מה המוצר שאתם מחפשים ונשלח אליכם הצעת מחיר/נחזור אליכם

    דילוג לתוכן