Discovery DSC 2500 Differential Scanning Calorimeter

The Discovery DSC 2500 is the top model in the Discovery DSC series. Moreover, it measures heat capacity in a single run. Bargal represents TA Instruments in Israel.

  • T4P Tzero heat flow
  • Included 54-position autosampler
  • Baseline flatness ≤5 µW (-50 to 300 °C)
  • Modulated DSC (MDSC) as standard
תיאור

The Discovery DSC 2500 is the top model in the Discovery DSC series. It combines the highest sensitivity with advanced T4P Tzero heat flow. As a result, you can measure heat capacity in a single run. Moreover, a 54-position autosampler is included. In Israel, Bargal supplies the DSC 2500.

Who is the Discovery DSC 2500 for?

TA designed the DSC 2500 for researchers who need the highest level of performance. It is also ideal for busy labs that run samples around the clock. Typical users include:

  • Research groups in polymers, materials and pharmaceutical science
  • R&D teams that also must detect weak or overlapping thermal transitions
  • Labs that measure heat capacity as part of their routine work
  • High-throughput labs that also need unattended, 24/7 operation

Applications

  • Polymers: weak glass transitions, crystallinity and curing kinetics
  • Pharmaceuticals: amorphous content, polymorphs and stability
  • Heat capacity (Cp) measurements, in a single run
  • Complex materials: separating overlapping events with Modulated DSC
  • Foods and fats: crystallization and melting behavior

Key features

  • T4P Tzero heat flow, for the sharpest resolution and direct heat-capacity data
  • Fusion Cell, with the flattest baseline in the Discovery DSC range
  • Modulated DSC (MDSC), to separate complex thermal events
  • Included 54-position autosampler, as well as automated calibration and verification
  • App-style touchscreen, for simple one-touch operation
  • Optional refrigerated cooling to -120 °C, so you avoid liquid nitrogen

Technical specifications

Parameter DSC 2500
Baseline flatness (-50 to 300 °C) ≤5 µW
Baseline repeatability (-50 to 300 °C) <10 µW
Temperature range -180 to 725 °C, depending on the cooling accessory
Temperature accuracy ±0.025 °C
Temperature precision ±0.005 °C
Enthalpy precision ±0.04%
Heat flow Advanced Tzero (T4P)
Direct Cp measurement Yes
Modulated DSC (MDSC) Standard
Autosampler Included, 54 positions

Cooling depends on the accessory. For example, the RCS 120 refrigerated system reaches -120 °C. In addition, the liquid nitrogen pump reaches -180 °C and works up to 550 °C. The finned air cooling system covers ambient to 725 °C.

 

You can also read the full details on the official TA Instruments DSC 2500 page.

 

Frequently asked questions

What is the difference between the DSC 2500 and the DSC 25?

Both use the Fusion Cell and standard MDSC. However, the DSC 2500 adds T4P heat flow, direct heat capacity and an included autosampler.

What does T4P Tzero heat flow mean?

It accounts for the contribution of the sample pans. As a result, it gives sharper resolution and heat capacity in one run.

Is an autosampler included?

Yes. The DSC 2500 includes the 54-position autosampler.

What is the DSC 2500 used for?

The DSC 2500 measures melting, crystallization, glass transitions, curing and heat capacity. Therefore, it suits research and high-throughput labs.

 

Also see the Discovery DSC 25 differential scanning calorimeter.

 

For mass-change measurements, see the Discovery TGA 550 thermogravimetric analyzer.