The Discovery HR 30 is a premier research-grade hybrid rheometer. Moreover, it measures torque as low as 0.15 nN·m in oscillation. Bargal represents TA Instruments in Israel.
The Discovery HR 30 rheometer is a premier research-grade hybrid rheometer from TA Instruments. It measures torque as low as 0.15 nN·m in oscillation. Also, this sensitivity suits research on weak structures and low-viscosity fluids. In addition, integrated linear DMA makes it a two-in-one instrument for solids. In Israel, Bargal represents TA Instruments.
The HR 30 suits advanced research that needs high sensitivity. It is also useful when sample volume is small. Typical users include:
| Parameter | HR 30 |
| Minimum torque, oscillation | 0.15 nN·m |
| Minimum torque, rotation | 1 nN·m |
| Maximum torque | 250 mN·m |
| Torque resolution | 0.01 nN·m |
| Frequency range | 1.0E-07 to 250 Hz |
| Maximum angular velocity | 315 rad/s |
| Displacement resolution | 2 nrad (dual-reader optical encoder) |
| Normal force | Sensitivity 0.005 N, maximum 50 N (Force Rebalance Transducer) |
| Integrated linear DMA, axial frequency | 10-5 to 16 Hz |
| Integrated linear DMA, axial force | 3 mN to 50 N |
| Bearings and motor | Magnetic thrust bearing, porous carbon radial bearings, drag cup motor |
You can also read the full details on the official TA Instruments HR 30 page.
What is the difference between the HR 30 and the HR 10?
Both belong to the Discovery Hybrid Rheometer family. However, the HR 30 reaches a lower minimum torque. It also has a dual-reader encoder and finer torque resolution.
When do I need the HR 30?
Consider it for low-viscosity, weak or scarce samples. For general viscosity and viscoelasticity work, the HR 10 may be enough.
Can the HR 30 test solid samples?
Yes. Its integrated linear DMA measures E', E" and tan δ in tension, bending and compression. Moreover, the available modes depend on the environmental system.
Also see the Discovery HR 10 hybrid rheometer.
For separate motor and transducer, see the ARES-G3 rheometer.
Interested in the Discovery HR 30? Send us an enquiry, and our team will respond quickly. We are also happy to discuss your samples and your application.
ראומטר Discovery HR 30 של TA Instruments, ראומטר מחקר מתקדם למדידת נוזלים בצמיגות נמוכה וג׳לים חלשים, עם DMA ליניארי משולב – ברגל ציוד אנליטי, נציגת TA Instruments בישראל.
יש באתר שלנו מאות מוצרים וגם זה עוד לא הכל. אם לא בא לכם לחפש, אתם יכולים פשוט לכתוב כאן בתיבת הצ'אט מה אתם מחפשים ואנחנו נחזור אליכם כמה שיותר מהר עם כל התשובות. ֿ צוות ברגל ציוד אנליטי
היי! שמחים שהגעתם לאתר שלנו! באתר יש כרגע מאות מוצרים ואנחנו מוסיפים מוצרים כל הזמן. אם לא מצאתם את מה שחיפשתם או שאין לכם כוח לחפש (קורה לכולנו), כתבו לנו כאן מה המוצר שאתם מחפשים ונשלח אליכם הצעת מחיר/נחזור אליכם