Hybrid Rheometer – HR 30

The Discovery HR 30 is a premier research-grade hybrid rheometer. Moreover, it measures torque as low as 0.15 nN·m in oscillation. Bargal represents TA Instruments in Israel.

  • Minimum oscillation torque 0.15 nN·m
  • Dual-reader encoder
  • Magnetic thrust bearing
  • Integrated linear DMA
תיאור

The Discovery HR 30 rheometer is a premier research-grade hybrid rheometer from TA Instruments. It measures torque as low as 0.15 nN·m in oscillation. Also, this sensitivity suits research on weak structures and low-viscosity fluids. In addition, integrated linear DMA makes it a two-in-one instrument for solids. In Israel, Bargal represents TA Instruments.

Who is the Discovery HR 30 rheometer for?

The HR 30 suits advanced research that needs high sensitivity. It is also useful when sample volume is small. Typical users include:

  • Research groups that study soft materials and weak structures
  • R&D scientists who also work with low-viscosity or weak samples
  • Polymer labs that want guided methods for melts and Tg analysis
  • Labs that also want linear DMA on solids in the same instrument

Applications

  • Thin liquids: accurate low-viscosity data
  • Weak gels and soft solids: gentle, low-stress measurements
  • UV-curing resins: curing and gelation, with the optional UV Curing accessory
  • Polymers: melts, as well as solids and transition temperatures such as Tg with linear DMA

Key features

  • Minimum oscillation torque of 0.15 nN·m, for weak samples and small volumes
  • Dual-reader encoder, with 70% better phase-angle precision and 5× finer displacement resolution
  • Magnetic thrust bearing, so it cuts system friction by 70% compared with traditional designs
  • Integrated linear DMA, so no external components are required
  • Smart Swap geometries and temperature systems, detected automatically
  • TRIOS software, with Fast Frequency Chirps, so curing and gelation tests finish quicker

Technical specifications

Parameter HR 30
Minimum torque, oscillation 0.15 nN·m
Minimum torque, rotation 1 nN·m
Maximum torque 250 mN·m
Torque resolution 0.01 nN·m
Frequency range 1.0E-07 to 250 Hz
Maximum angular velocity 315 rad/s
Displacement resolution 2 nrad (dual-reader optical encoder)
Normal force Sensitivity 0.005 N, maximum 50 N (Force Rebalance Transducer)
Integrated linear DMA, axial frequency 10-5 to 16 Hz
Integrated linear DMA, axial force 3 mN to 50 N
Bearings and motor Magnetic thrust bearing, porous carbon radial bearings, drag cup motor

 

You can also read the full details on the official TA Instruments HR 30 page.

Frequently asked questions

What is the difference between the HR 30 and the HR 10?

Both belong to the Discovery Hybrid Rheometer family. However, the HR 30 reaches a lower minimum torque. It also has a dual-reader encoder and finer torque resolution.

When do I need the HR 30?

Consider it for low-viscosity, weak or scarce samples. For general viscosity and viscoelasticity work, the HR 10 may be enough.

Can the HR 30 test solid samples?

Yes. Its integrated linear DMA measures E', E" and tan δ in tension, bending and compression. Moreover, the available modes depend on the environmental system.

 

Also see the Discovery HR 10 hybrid rheometer.

For separate motor and transducer, see the ARES-G3 rheometer.

 

Interested in the Discovery HR 30? Send us an enquiry, and our team will respond quickly. We are also happy to discuss your samples and your application.

 

 