Orbitrap Eclipse Tribrid

Tribrid mass spectrometer system.

Features and Benefits of the Orbitrap Eclipse Tribrid MS

Power high impact science with performance advancements
Address complex challenges more effectively with the latest improvements in calibration, ion transmission efficiency, mass range, data acquisition speed and much more!

Gain ultimate flexibility with the ability to expand your experimental scope


תיאור

You need LC-MS workflows to push today’s limits. The Orbitrap Eclipse Tribrid MS comes with enhanced sensitivity, selectivity and more MSn techniques, scan modes and intelligence. It’s now possible to go beyond your scientific pursuits with the ability to expand your experimental scope.

Obtain highest quality MS data with built-in intelligence

The Orbitrap Eclipse Tribrid MS eliminates convoluted optimization procedures by providing pre-defined data acquisition methods, pre-set instrument parameters and built-in intelligence for workflows including TMT. No compromises on data quality needed.

Improve your laboratory productivity with a single system that provides maximum insights
The ability to go beyond today’s discovery is now possible with one mass spectrometer built to solve analytical challenges for proteomics, structural biology, small molecule research and biopharmaceutical services.

Performance Characteristics of the Orbitrap Eclipse Tribrid MS

Orbitrap Mass Range:

Standard mass range m/z 50–2000
Mid-mass range m/z 200–6000
HMRnmass range m/z 500–8000

Orbitrap Resolution:

Standard resolution settings range from 7500 to 500,000 (FWHM) at m/z 200,
Up to 1,000,000 (FWHM) at m/z 200 with 1M option

Acquisition Rate:

Orbitrap MSn acquisition rates up to 40 Hz
Linear ion trap MSn acquisition rates up to 45 Hz

Orbitrap Mass Accuracy:

<3 ppm RMS drift over 24 hours using external calibration
<1 ppm RMS drift over 24 hours using internal calibration Dynamic Range: >5000 within a single Orbitrap mass spectrum

MS Scan Power:

Collects MSn for n = 1 through 10, detected in either the Orbitrap or linear ion trap mass analyzers

Synchronous Precursor Isolation:

Samples up to 20 precursors per MSn scan

Precursor Multiplexing:

Up to 10 precursors can be multiplexed using the quadrupole mass filter and ion-routing multipole to perform selected ion monitoring or tandem MS

Polarity Switching

One full experimental cycle acquired in <1.1 seconds where the cycle consists of acquiring one full MS scan in positive and negative polarity at a resolution setting of 30,000