The Thermo Scientific™ Orbitrap Fusion™ Tribrid™ mass spectrometer combines the best of quadrupole, Orbitrap, and ion trap mass analysis in a revolutionary Tribrid architecture that delivers unprecedented depth of analysis.
It enables life scientists analyzing even the most challenging low-abundance, high-complexity, or difficult samples to identify more compounds more quickly, quantify
more accurately, and elucidate structures more thoroughly.
Unique Features of the Orbitrap Fusion:
Combining the best of quadrupole, Orbitrap, and ion trap mass analysis in a revolutionary Tribrid architecture, the Orbitrap Fusion Tribrid mass spectrometer delivers unmatched analytical performance with revolutionary depth of analysis, unprecedented usability, and exceptional robustness.
Performance Characteristics of the Orbitrap Fusion:
Mass Range:
Linear Ion Trap and Orbitrap Mass Range:
Standard – m/z 50–2,000
High Mass – m/z 200–4,000
Orbitrap Extended Mass Range:
Up to m/z 6000 without precursor ion selection
Resolution:
15,000-450,000 (FWHM) at m/z 200
Scan Rate:
Orbitrap MSn up to 20 Hz
Ion trap MSn up to 20 Hz
Mass Accuracy:
< 3 ppm RMS using external calibration
< 1 ppm RMS using internal calibration
MS/MS Sensitivity of Ion Trap:
2 μL of a 50 fg/μL solution of reserpine (100 fg total) injected at a flow of 500 μL/min will produce a minimum signal-to-noise ratio of 100:1 for the transition of the isolated protonated molecular ions at m/z 609 to the largest two product ions, m/z 397 and m/z 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, m/z 165–615. The test requires the HESI probe.
Dynamic Range:
> 5,000 within a single scan, guaranteeing specified mass accuracy
MS Scan Power:
MSn, for n = 1 through 10
Thermo Scientific™ EASY-ETD™ Ion Source:
• Townsend discharge ionization is extremely stable and robust
• Compact size, located entirely within the footprint of the instrument
• Active reagent ion filtering using mass-resolving quadrupole
Thermo Scientific™ EASY-IC™ Ion Source:
• Provides <1 ppm RMS mass accuracy
Synchronous Precursor Selection
Up to 15 precursors per MS2 scan, for MS3 analysis only
Multiplexing Using Ion-Routing Multipole:
Up to 10 precursors per scan using quadrupole mass filter
Polarity Switching:
One full cycle in 1.1 sec (one full scan in positive mode and one full scan in negative mode at resolution setting of 35,000)